Bug #380
Als Tool:When page number is wrong,processing the procedure,it does not have any prompt in log file.
Description
Als Tool:When page is wrong,processing the procedure,it does not have any prompt in log file.
1.If the page number of the alarm pic only has 2/2(see attachment pic1) like the alarm(0DVQ001KA) in the file(see attachment test1)
Expected Result:*the log file show that it does not have page 1/2 in the file.
*Actual Result: it does not have any prompt.
2.If there are two more alarm have the same name like the alarm(0DVQ051KA) in the file(see attachment test3),and the page numbers are 1/1,1/2,2/2,1/3,2/3,3/3
Expected Result:*the log file should show that the alarm have the same name.
*Actual Result: it does not have any prompt,and the alarm pic which the page numbers are 1/1,1/2,2/3 genrate.
comments: The rule generates the pic of the person who appears first. Please report an error if the following name is repeated.
zhouxuan_reopen_20220317_v1.1.0
The above problems still exist
zhouxuan_reopen_20220421_v1.1.4
1.Run the attachment test32.doc
2.see the 1.png. the 1RCP609KA have repeated ID, but all be created correctly.
3.see the 2.png. the 1RCP609KAa should warn repeated ID, not error.
zhouxuan_reopen_20220427_v1.1.5
1.The alarm sheet 1CFI901KA1 created Second rather than first appear.
2.前面已经生成一页的609KAa了 后面的这些609KAa有报title有报重复ID,请确认,见bug.png
Zhouxuan_20220505_validate_ok_Als Tool 1.1.6
History
#1 Updated by hwyang over 3 years ago
- Status changed from Reserved to Opened
#2 Updated by hwyang over 3 years ago
- Assignee changed from hwyang to zzy
#3 Updated by Anonymous over 3 years ago
- Status changed from Opened to Completed
#5 Updated by Anonymous over 3 years ago
- Status changed from Opened to Completed
The format of all serial numbers must be one of 1/1, 1/2, 2/2, 1/3, 2/3, 3/3, otherwise an error will be reported. If all 1/1, 1/2, 2/2, 1/3, 2/3, 3/3 are included, only 1/3, 2/3, 3/3 will be generated. If only 1/1,1/2,2/2, only generate 1/2,2/2 corresponding
see path https://117.78.0.17:8443/svn/gz/tool/Alarm_sheet/tags/1.0.8/runpanel
#6 Updated by zhouxuan over 3 years ago
- Description updated (diff)
- Status changed from Completed to Opened
#7 Updated by Anonymous over 3 years ago
- Status changed from Opened to Completed
#8 Updated by zhouxuan over 3 years ago
- Description updated (diff)
- Status changed from Completed to Opened
#9 Updated by Anonymous over 3 years ago
- Status changed from Opened to Completed
#10 Updated by zhouxuan over 3 years ago
- Description updated (diff)
- Status changed from Completed to Validated
- Additional info. set to Zhouxuan_20220406_validate_ok_Als Tool 1.1.2
#11 Updated by zhouxuan over 3 years ago
- File 1.png 1.png added
- File 2.png 2.png added
- File test32.doc test32.doc added
- Description updated (diff)
- Status changed from Validated to Opened
- Additional info. deleted (
Zhouxuan_20220406_validate_ok_Als Tool 1.1.2)
#12 Updated by Anonymous over 3 years ago
- Status changed from Opened to Completed
#14 Updated by Anonymous over 3 years ago
- Status changed from Opened to Completed
#15 Updated by zhouxuan over 3 years ago
- Description updated (diff)
- Status changed from Completed to Validated
- Additional info. set to Zhouxuan_20220505_validate_ok_Als Tool 1.1.6