Activity
From 01/14/2022 to 02/12/2022
02/11/2022
- 05:47 PM Bug #376 (Completed): Als:If there are two or more alarm'name is same in the file,all the alarm pic in the file will not generate.
- This problem has been solved , Please test use latest version.
path : https://117.78.0.17:8443/svn/gz/tool/Alarm_s... - 11:08 AM Bug #376 (Opened): Als:If there are two or more alarm'name is same in the file,all the alarm pic in the file will not generate.
- 11:08 AM Bug #376 (Validated): Als:If there are two or more alarm'name is same in the file,all the alarm pic in the file will not generate.
- Als:If there are two or more alarm'name is same in the file,all the alarm pic will not generate.
When there are ... - 05:46 PM Bug #373: Als:When the alarm pic is multiple sheets,its size is 1084*813
- This problem has been solved , Please test use latest version.
path : https://117.78.0.17:8443/svn/gz/tool/Alarm_s... - 05:46 PM Bug #373 (Completed): Als:When the alarm pic is multiple sheets,its size is 1084*813
- This problem has been solved , Please test use latest version.
path : https://117.78.0.17:8443/svn/gz/tool/Alarm_s... - 11:07 AM Bug #373 (Opened): Als:When the alarm pic is multiple sheets,its size is 1084*813
- 05:25 PM Bug #375 (Completed): Als Tool:If the colour of the alarm is wrong,it does not have any prompt in the log file
- The program judges whether it is a normal table according to the color range of the first row and the first column. I...
- 11:05 AM Bug #375 (Opened): Als Tool:If the colour of the alarm is wrong,it does not have any prompt in the log file
- 10:49 AM Bug #375 (Validated): Als Tool:If the colour of the alarm is wrong,it does not have any prompt in the log file
- Als Tool:If the colour of the alarm is wrong,it does not have any prompt in the log file
When the colour in the t... - 04:30 PM Bug #371 (Completed): Als tool:The alarm pic doesn't generated
- If two tables have same alarm id and serial number , it will show log "Wrong serial number" .
- 11:10 AM Bug #371 (Opened): Als tool:The alarm pic doesn't generated
- 04:03 PM Bug #367 (Completed): Als tool: Miss one alarm pic (2KIC014KA ) when processing alarm procedure
- This problem has been solved , Please test use latest version.
path : https://117.78.0.17:8443/svn/gz/tool/Alarm... - 04:00 PM Bug #368 (Completed): Als tool:If the alarm is purple,the alarm pic doesn't generated
- This problem has been solved , Please test use latest version.
path : https://117.78.0.17:8443/svn/gz/tool/Alarm... - 11:11 AM Bug #368 (Opened): Als tool:If the alarm is purple,the alarm pic doesn't generated
- 03:59 PM Bug #374 (Completed): Als:The alarm pic(9RRB998KA) displays the content in other table.
- This problem has been solved , Please test use latest version.
path : https://117.78.0.17:8443/svn/gz/tool/Alarm... - 11:06 AM Bug #374 (Opened): Als:The alarm pic(9RRB998KA) displays the content in other table.
- 11:10 AM Bug #369 (Opened): Als tool:The display of alarm pic is different to the table
- 11:10 AM Bug #370 (Opened): Als tool:The content can’t display completely,if it is hide in table.
02/10/2022
- 06:06 PM Bug #374 (Validated): Als:The alarm pic(9RRB998KA) displays the content in other table.
- Als:The alarm pic(9RRB998KA) displays the content in other table.
When Processing the file 'A9RRB000 Boron Heat Tr... - 05:57 PM Bug #373 (Validated): Als:When the alarm pic is multiple sheets,its size is 1084*813
- Als:When the alarm pic is multiple sheets,its size is 1084*813
When the alarm pic is multiple sheets
*Expected Re... - 04:22 PM Bug #371 (Validated): Als tool:The alarm pic doesn't generated
- Als tool:The alarm pic doesn't generated
When Processing the file 'A0DVQ000 DVQ Ventilation System REV002 01' (see... - 02:41 PM Bug #370 (Validated): Als tool:The content can’t display completely,if it is hide in table.
- Als tool:The content can’t display completely,if it has been hide in table.
1.When the content is hided in the tab... - 02:23 PM Bug #369 (Validated): Als tool:The display of alarm pic is different to the table
- Als tool:The display of alarm pic is different to the table
1.When Processing the file 'A2LAA000 Alarm procedures ... - 12:01 PM Bug #367 (Opened): Als tool: Miss one alarm pic (2KIC014KA ) when processing alarm procedure
- 11:16 AM Bug #367 (Validated): Als tool: Miss one alarm pic (2KIC014KA ) when processing alarm procedure
- Als tool: Miss one alarm pic (2KIC014KA ) when processing alarm procedure
When Processing the file 'A2KIC000 Power... - 11:36 AM Bug #368 (Validated): Als tool:If the alarm is purple,the alarm pic doesn't generated
- Als tool:If the alarm is purple,the alarm pic not generated
When Processing the purple alarm
*Expected Result:*T...